Information analysis of single photon emission computed tomography with count losses
Abstract:
An analysis is presented of the information transfer from emitter-space to detector-space in single photon emission computed tomography (SPECT) systems. The analysis takes into account the fact that count loss side information is generally not available at the detector. Side information corresponds to the number gamma-rays lost deleted due to lack of interaction with the detector data. It is shown that the information transfer depends on the structure of the likelihood function of the emitter locations associated with the detector data. This likelihood function is the average of a set of ideal-detection likelihood functions, each matched to a particular set of possible deleted gamma-ray paths. A lower bound is derived for the information gain due to incorporating the count loss side information at the detector. This is shown to be significant when the mean emission rate is small or when the gamma-ray deletion probability is strongly dependent on emitter location. Numerical evaluations of the mutual information, with and without side information, associated with information-optimal apertures and uniform parallel-hole collimators are presented.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET