Cross-plane scattering correction-point source deconvolution in PET.

L Shao1, J S Karp

  • 1Dept. of Radiol., Pennsylvania Univ., Philadelphia, PA.

IEEE Transactions on Medical Imaging
|January 1, 1991
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[Efficacy and safety of pixavir marboxil for uncomplicated influenza in adults: a phase Ⅱ, randomized, double-blind, placebo-controlled clinical trial].

Zhonghua jie he he hu xi za zhi = Zhonghua jiehe he huxi zazhi = Chinese journal of tuberculosis and respiratory diseases·2026
Same author

First Detection of Ultrahigh Energy Emission from Gamma-Ray Binary LS I +61° 303.

Physical review letters·2026
Same author

Evidence of Cosmic-Ray Acceleration up to Sub-PeV Energies in the Supernova Remnant IC 443.

Physical review letters·2026
Same author

Precise Measurement of the Cosmic Ray Helium Spectrum above 0.1 PeV.

Physical review letters·2026
Same author

Black Hole Spectroscopy and Tests of General Relativity with GW250114.

Physical review letters·2026
Same author

[Digital measurement and analysis of anatomical characteristics of protrusive and intercuspal position occlusal contacts in maxillary incisors].

Beijing da xue xue bao. Yi xue ban = Journal of Peking University. Health sciences·2026
Same journal

Informed-Exploration Reinforcement Learning for Automated Virtual Coronary Intervention Planning.

IEEE transactions on medical imaging·2026
Same journal

4D Reconstruction of Fetal Left Ventricle from Echocardiography via 2.5D Radial Segmentation and Graph-Fourier Reconstruction.

IEEE transactions on medical imaging·2026
Same journal

Generalised Medical Phrase Grounding.

IEEE transactions on medical imaging·2026
Same journal

EndoLRMGS: Combining Large Reconstruction Modelling and Gaussian Splatting for Complete Endoscopic Scene Reconstruction.

IEEE transactions on medical imaging·2026
Same journal

A Neural-Analytical Fusion Scatter Correction Method for Multi-Source CT Using Equivalent High-Order Scatter.

IEEE transactions on medical imaging·2026
Same journal

SynReEM: Synapse Reconstruction via Instance Structure Encoding in Anisotropic Electron Microscopic Volumes.

IEEE transactions on medical imaging·2026
See all related articles

This study introduces a novel 2-D point source scattering deconvolution method that accurately models cross-plane scattering. This advanced technique improves scatter fraction estimation in medical imaging compared to standard methods.

Area of Science:

  • Medical Imaging
  • Image Reconstruction
  • Signal Processing

Background:

  • Accurate scatter correction is crucial for quantitative analysis in emission imaging.
  • Existing methods often struggle to fully account for complex scattering phenomena.

Purpose of the Study:

  • To develop and validate a new 2-D point source scattering deconvolution method.
  • To improve the accuracy of scatter fraction estimation in emission imaging.

Main Methods:

  • Modeling cross-plane scattering using a scattering point source function.
  • Estimating exponential fitting parameters from measured point response functions.
  • Comparing the proposed method with standard in-plane line source deconvolution.

Main Results:

Related Experiment Videos

  • The new method accurately incorporates cross-plane scattering.
  • Standard methods overestimate scatter in-plane and underestimate it in adjacent planes.
  • The proposed method offers improved scatter fraction estimation.

Conclusions:

  • The novel 2-D point source scattering deconvolution method enhances scatter correction accuracy.
  • This technique provides a more precise way to handle scattering in medical imaging.
  • A simple approximation technique for deconvolution is also presented.