Related Experiment Video
Updated: Jun 28, 2026

Assessing Cortical Cerebral Microinfarcts on High Resolution MR Images
Published on: November 20, 2015
Intracranial contrast-enhanced magnetic resonance venography with 6.4-fold sensitivity encoding at 1.5 and 3.0 Tesla
Houchun H Hu1, Clifton R Haider, Norbert G Campeau
1University of Southern California, Department of Electrical Engineering, Los Angeles, CA, USA.
Purpose:
To prospectively compare vessel conspicuity and diagnostic image quality between three-dimensional intracranial contrast-enhanced MR venography acquired at 1.5 Tesla (T) and 3.0T, with 6.4-fold sensitivity encoding.
Materials And Methods:
Ten healthy volunteers were imaged on 1.5T and 3.0T MR scanners using eight-element head coil arrays. The intracranial venous vasculature was divided into five groups for evaluation based on vessel size and anatomical location. Two radiologists independently assessed vessel conspicuity, level of artifacts, and diagnostic image quality. Informed consent was obtained, and the study was approved by the institutional review board.
Results:
With the exception of large cerebral sinuses where 1.5T and 3.0T results were rated as equivalent, 3.0T images demonstrated superior vessel continuity, sharpness, and signal contrast to background tissue than 1.5T for all other intracranial venous vasculature (P < 0.01). No statistical significance in overall image quality was found between 1.5T and 3.0T venograms, and all data sets were deemed sufficient for diagnostic interpretation.
Conclusion:
Whole brain contrast-enhanced venography with 6.4-fold sensitivity encoding is robust and has the potential to become the method of choice for fast visualization of the intracranial venous vasculature. At 3.0T, demonstration of small cerebral vessels is superior to 1.5T.
Related Concept Videos
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging

