Interference of chitosan in glucose analysis by high-performance liquid chromatography with evaporative light
B N Estevinho1, A Ferraz, F Rocha
1LEPAE, Departamento de Engenharia Química, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal.
Abstract:
The purpose of this work was to quantify glucose in aqueous solutions containing chitosan by high-performance liquid chromatography (HPLC) with evaporative light scattering detection (ELSD). Chitosan is a natural compound that is used alone or as an additive in several formulations. Microencapsulation of bioactive compounds such as glucose, by means of chitosan, is being explored, but difficulties arise when glucose needs to be determined in the presence of chitosan. HPLC is the technique most commonly used for glucose analysis, and ELSD may offer advantages (e.g. sensitivity and the possibility of operating in gradient mode) compared with other detectors. The influence of chitosan in the analysis of glucose by HPLC with ELSD was investigated at different pH values of the aqueous solutions. Isocratic elution with an acetonitrile/water mixture (80:20, v/v) and water washing between runs were the best options to avoid the mucoadhesive properties of chitosan, which are responsible for column degradation and variability of the retention time of glucose. The developed methodology was considered completely adequate for rapid glucose analysis in aqueous solutions with low pH (< 3), in the presence of chitosan.
More Related Videos
12:02Automated Modular High Throughput Exopolysaccharide Screening Platform Coupled with Highly Sensitive Carbohydrate Fingerprint Analysis
Published on: April 11, 2016
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
High-Performance Liquid Chromatography: Instrumentation
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Elution Process