Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
A sensitive PARACEST contrast agent for temperature MRI: Eu3+-DOTAM-glycine (Gly)-phenylalanine (Phe)
Alex X Li1, Filip Wojciechowski, Mojmir Suchy
1Center for Functional and Metabolic Mapping, Robarts Research Institute, 100 Perth Drive, London, Ontario, Canada.
Abstract:
Tissue temperature is a fundamental physiological parameter that can provide insight into pathological processes. The purpose of this study was to develop and characterize a novel paramagnetic chemical exchange saturation transfer (CEST) agent suitable for in vivo temperature mapping at 9.4T. The CEST properties of the europium (Eu(3+)) complex of the DOTAM-Glycine (Gly)-Phenylalanine (Phe) ligand were studied in vitro at 9.4T as a function of temperature, pH, and agent concentration. The transfer of magnetization (CEST effect) from the bound water to bulk water pools was approximately 75% greater for Eu(3+)-DOTAM-Gly-Phe compared to Eu(3+)-DOTAM-Gly at physiologic temperature (38 degrees C) and pH (7.0 pH units) when using power level sufficiently low for in vivo imaging. Unlike Eu(3+)-DOTAM-Gly, whose CEST effect decreased with increasing temperature in the physiologic range, the CEST effect of Eu(3+)-DOTAM-Gly-Phe was optimal at body temperature. A strong linear dependence of the chemical shift of the bound water pool on temperature was observed (0.3 ppm/ degrees C), which was insensitive to pH and agent concentration. Temperature maps with SDs < 1 degrees C were acquired at 9.4T in phantoms containing: 1) phantom A, an aqueous solution of 10 mM Eu(3+)-DOTAM-Gly-Phe; 2) phantom B, 5% bovine serum albumin (BSA) with 15 mM Eu(3+)-DOTAM-Gly-Phe; and 3) phantom C, mouse brain tissue with 4 mM Eu(3+)-DOTAM-Gly-Phe. The temperature sensitivity combined with the high CEST effect observed at low concentration using low saturation power (B(1)) suggests this compound may be a good choice for in vivo temperature mapping at 9.4T.
Related Concept Videos
Magnetic Resonance Imaging
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies for Cardiovascular System IV: CMRI