A fast reconstruction algorthm for stationary positron emission tomography based on a modified em algorithm
Related Experiment Video
Updated: Jul 7, 2026

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Abstract:
An efficient iterative reconstruction method for positron emission tomography (PET) is presented. The algorithm is basically an enhanced EM (expectation maximization) algorithm with improved frequency response. High-frequency components of the ratio of measured to calculated projections are extracted and are taken into account for the iterative correction of image density in such a way that the correction is performed with a uniform efficiency over the image plane and with a flat frequency response. As a result, the convergence speed is not so sensitive to the image pattern or matrix size as the standard EM algorithm, and nonuniformity of the spatial resolution is significantly improved. Nonnegativity of the reconstructed image is preserved. Simulation studies have been made assuming two PET systems: a scanning PET with ideal sampling and a stationary PET with sparse sampling. In the latter, a "bank array" of detectors is employed to improve the sampling in the object plane. The new algorithm provides satisfactory images by two or three iterations starting from a flat image in either case. The behavior of convergence is monitored by evaluating the root mean square of C(b)-1 where C(b) is the correction factor for pixel b in the EM algorithm. The value decreases rapidly and monotonically with iteration number. Although the theory is not accurate enough to assure the stability of convergence, the algorithm is promising to achieve significant saving in computation compared to the standard EM algorithm.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...