A novel noninvasive measurement technique for analyzing the pressure pulse waveform of the radial artery
Chu-Chang Tyan1, Shing-Hong Liu, Jan-Yow Chen
1Graduate Institute of Chinese Medical Science, China Medical University (CMU), China Medical University Hospital (CMUH), Taichung, Taiwan.
Abstract:
Previous noninvasive measurements of the pulse waveform of the radial artery have not employed standard positioning procedures. Here, we propose a new noninvasive measuring apparatus that has a two-axis mechanism and employs a standard positioning procedure for detecting the optimal site for accurately measuring the pressure pulse waveform (PPW). A modified sensor was designed to simultaneously measure the arterial diameter changed waveform (ADCW) and PPW. Considering the artery as a cylinder, the measured waveform would be distorted if the sensor were not at the middle of arterial width. Moreover, a blood vessel is elastic, and its compliance changes with the transmural pressure, being maximal when the transmural pressure is equal to zero. The sensor should detect the PPW with the lowest possible distortion and, hence, an analysis of the vascular geometry and an arterial model were used to design a standard positioning procedure based on the ADCW for the X and Z axes. In order to verify the resolution of the X axis scanning procedure, the echo method was used to measure the radial artery outer diameter in ten healthy subjects. The difference between the scanning width and the actual arterial diameter was 0.36 +/- 0.23 mm (mean +/- SD). Finally, the PPW as measured at the optimal position was used to diagnose myocardial ischemia symptoms in 60 elderly subjects whose chief complaint was chest pain, with the exercise electrocardiogram being used as a reference to compare between individuals with and without myocardial ischemia. The PPW analysis used the harmonic components in the frequency domain. We found that the fourth harmonic of the Fourier series differed significantly between the groups (p = 0.0039), which is consistent with previous studies. The results indicate that our noninvasive measurement apparatus is very suitable for analyzing the PPW of the radial artery.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse
The pulse serves as a clinical indicator...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)