Related Experiment Video
Updated: Jul 7, 2026

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
The Effect of Accidental Coincidences in Time-of-Flight Positron Emission Tomography
Abstract:
An accidental coincidence is defined as the erroneous registration of two photons, originating from separate positron annihilations, as having originated from the same positron annihilation. Previous analyses which did not consider accidental coincidences indicated that for a certain radioactivity distribution a gain in image signal-to-noise ratio of about 5 dB is achieved by the time-of-flight method over the conventional method. Subsequent experiments have validated this prediction in low counting rate situations. For higher, typical counting rates these experiments showed a significantly larger gain of about 9 dB, which was attributed to the way in which the time-of-flight method suppresses the degrading effects of accidental coincidences. We present an analytical model, extended from a previous model, which considers accidental coincidences. Calculations of signal-to-noise ratio, using this model, compare well with the experiments and show that the additional gain is indeed due to the treatment of accidental coincidences. An understanding of the model leads to an intuitive explanation of the gain mechanism and a determination of an effective coincidence-timing window that is achieved by the time-of-flight method.
More Related Videos
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...