Related Experiment Video
Updated: Jul 7, 2026

Visualization and Analysis of Blood Flow and Oxygen Consumption in Hepatic Microcirculation: Application to an Acute Hepatitis Model
Published on: August 4, 2012
Results of the oxygen Fick method in a closed blood circulation model including "total arteriovenous diffusive shunt
1Department of Physiology, Medical Faculty of C. B. University, 45030, Uncubozköy-Manisa, Turkey, mustafaoezbek@ttnet.net.tr.
Abstract:
It is considered that arteriovenous diffusive shunts of oxygen may cause inaccuracy of the oxygen Fick method as[Formula: see text] where[Formula: see text] is the pulmonary oxygen uptake,[Formula: see text] is the cardiac output, and CaO(2) and CvO(2) are the arterial and venous oxygen contents, respectively.A simple circulation model, including the whole circulation with nine well-mixed compartments (C1, ... C9), is constructed: the[Formula: see text] is assigned as constant as 6000 ml min(-1); the blood portions of 60 ml move at an interval of 600 ms. C1 and C2 compartments, each having 60 ml volume, represent the blood of pulmonary microcirculation, C3 represents the arterial blood with a volume of 1500 ml, C4, ..., C8, each also having a volume of 60 ml, represent the blood of peripheral microcirculation, whereas C9 represents the venous blood with a volume of 3000 ml. The pulmonary oxygen uptake[Formula: see text], related to C1 and C2, the oxygen release[Formula: see text], related to C4,...,C8, as well as a "total arteriovenous diffusive shunt of oxygen"[Formula: see text], from the arterial blood (C3) to the venous blood (C9), are calculated simultaneously. The alveolar gas has a constant oxygen partial pressure, and the pulmonary diffusion capacity is also constant; similar to modeling the pulmonry, oxygen diffusion, constant partial oxygen pressures for all peripheral tissues as well as constant diffusion capacities for all peripheral oxygen diffusion are also assigned. The diffusion capacities for the[Formula: see text] (between C3 and C9) are arbitrarily assigned.The Fick method gives incorrect results depending on the total arteriovenous diffusive shunt of oxygen[Formula: see text]. But the mechanism determining the magnitude of[Formula: see text] remains unclear.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
08:58Cerebral Blood Oxygenation Measurement Based on Oxygen-dependent Quenching of Phosphorescence
Published on: May 4, 2011
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
Oxygen Transport in the Blood
Gas Exchange and Transport
Respiration and Gaseous Exchange
Respiration involves the exchange of gases, especially oxygen (O2) and carbon dioxide (CO2), between the alveoli and body cells, a process facilitated by blood circulation. As a result, the cardiovascular system, which involves the...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.