Optimal screening of heart failure patients: tissue Doppler imaging or plasma NTpro BNP measurement?

Leo H B Baur1

  • 1Department of Cardiology, Atrium Medical Centre Parkstad, Henri Dunantstreet 5, 6401CX, Heerlen, The Netherlands. lbr01@atriummc.nl

Abstract

No abstract available in PubMed .

Related Concept Videos

Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers01:19

Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers

Cardiac biomarkers are critical in diagnosing, prognosing, and managing cardiovascular diseases. Routine measurement of specific biomarkers such as B-type natriuretic peptide (BNP), C-reactive protein (CRP), and homocysteine (Hcy) is common practice in clinical settings to evaluate heart function and predict cardiovascular events.
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...
Dysrhythmias V: Evaluating Dysrhythmias01:30

Dysrhythmias V: Evaluating Dysrhythmias

Dysrhythmias, also known as arrhythmias, are disturbances in the heart's rhythm that range from benign to life-threatening. A thorough evaluation is crucial for appropriate management and involves a comprehensive medical history, physical examination, and various diagnostic tests.Medical HistorySymptoms: Collect detailed information on palpitations, dizziness, syncope, chest pain, and fatigue. Note their onset, frequency, and triggers.Previous Cardiac Issues: Document any history of heart...
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...