Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Ultrasonography01:17

Ultrasonography

Ultrasonography is an imaging technique that uses high-frequency sound waves to visualize the body's internal structures. It is a non-invasive and safe procedure that does not involve the use of ionizing radiation, making it widely used in various medical fields. Ultrasonography is used to study heart function, blood flow in the neck or extremities, certain conditions such as gallbladder disease, and fetal growth and development.
During an ultrasonography procedure, a handheld device called a...
Ultrasound II: Endoscopic Ultrasound and FibroScan01:25

Ultrasound II: Endoscopic Ultrasound and FibroScan

Endoscopic Ultrasound (EUS) and FibroScan are valuable diagnostic tools in gastroenterology and hepatology, each with specific applications and techniques.
Endoscopic Ultrasound (EUS):
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies II: Ultrasonography01:24

Imaging Studies II: Ultrasonography

IntroductionUltrasonography, or renal ultrasound, is a noninvasive medical imaging technique that uses high-frequency sound waves to visualize the kidneys, ureters, bladder, and surrounding tissues.Indications for Urinary System UltrasonographyUrinary system ultrasonography is indicated in various clinical scenarios, such as:Kidney Stones (Urolithiasis): To detect and monitor the size and presence of kidney or urinary tract stones.Hydronephrosis: To assess the dilation of the renal pelvis and...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Characterizing the relationship between gonadotropin releasing hormone (GnRH), kisspeptin, and RFamide related peptide 3 (RFRP-3) neurons in the equine hypothalamus across the estrous cycle and in the anovulatory seasons.

Theriogenology·2024
Same author

Sex differences in the expression of estrogen receptor alpha within noradrenergic neurons in the sheep brain stem.

Domestic animal endocrinology·2014
Same author

Mode perturbation method for optimal guided wave mode and frequency selection.

Ultrasonics·2014
Same author

Lamb wave generation and reception with time-delay periodic linear arrays: a BEM simulation and experimental study.

IEEE transactions on ultrasonics, ferroelectrics, and frequency control·2008
Same author

Implementing guided wave mode control by use of a phased transducer array.

IEEE transactions on ultrasonics, ferroelectrics, and frequency control·2001
Same author

Mirizzi syndrome: A rare cause of obstructive jaundice.

Digestive diseases (Basel, Switzerland)·1999

Related Experiment Video

Updated: Jul 7, 2026

Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
09:02

Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population

Published on: January 31, 2025

Guided wave nuances for ultrasonic nondestructive evaluation.

J L Rose1

  • 1Engineering Science and Mechanics Department, University Park, PA 16802, USA. jlresm@engr.psu.edu

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
|February 2, 2008
PubMed
Summary

Guided wave testing enhances penetration and sensitivity for detecting hidden defects like corrosion and cracks in structures. Advanced transducers and signal processing enable precise flaw analysis in diverse applications.

More Related Videos

Ultrasound-based Pulse Wave Velocity Evaluation in Mice
08:07

Ultrasound-based Pulse Wave Velocity Evaluation in Mice

Published on: February 14, 2017

A Novel Application of Musculoskeletal Ultrasound Imaging
10:53

A Novel Application of Musculoskeletal Ultrasound Imaging

Published on: September 17, 2013

Related Experiment Videos

Last Updated: Jul 7, 2026

Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
09:02

Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population

Published on: January 31, 2025

Ultrasound-based Pulse Wave Velocity Evaluation in Mice
08:07

Ultrasound-based Pulse Wave Velocity Evaluation in Mice

Published on: February 14, 2017

A Novel Application of Musculoskeletal Ultrasound Imaging
10:53

A Novel Application of Musculoskeletal Ultrasound Imaging

Published on: September 17, 2013

Area of Science:

  • Materials Science
  • Mechanical Engineering
  • Nondestructive Evaluation

Background:

  • Guided wave testing advancements enable enhanced penetration power and sensitivity.
  • Tone burst function generators and signal processing are crucial for guided wave analysis.
  • Variable angle beam and comb-type transducers are key components for effective guided wave inspection.

Purpose of the Study:

  • To explore the potential of guided wave testing for increased penetration power and sensitivity.
  • To discuss applications in detecting hidden corrosion, bonding issues, and ice.
  • To develop configurations and logic for defect detection and analysis in complex structures.

Main Methods:

  • Utilizing tone burst function generators and advanced signal processing.
  • Employing variable angle beam and comb-type transducers.
  • Analyzing theoretical and experimental aspects including dispersion curves and boundary element models.

Main Results:

  • Demonstrated increased penetration power and sensitivity in guided wave testing.
  • Identified key applications in tubing, piping, aircraft, and bonding inspections.
  • Developed methodologies for defect detection in lap splice joints, cracks, and corrosion.

Conclusions:

  • Guided wave testing offers significant improvements for nondestructive evaluation.
  • Advanced transducer technology and signal processing are vital for sensitive defect detection.
  • The study provides a framework for analyzing complex flaws and material characterization.