Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Functional characterization of O-methyltransferases used to catalyse site-specific methylation in the post-tailoring steps of pradimicin biosynthesis.

Journal of applied microbiology·2017
Same author

Prediction of egg freshness during storage using electronic nose.

Poultry science·2017
Same author

VUV spectroscopy in impurity injection experiments at KSTAR using prototype ITER VUV spectrometer.

The Review of scientific instruments·2017
Same author

Localized argyria: troublesome side-effect of acupuncture.

Journal of the European Academy of Dermatology and Venereology : JEADV·2017
Same author

Possible electric field induced indirect to direct band gap transition in MoSe<sub>2</sub>.

Scientific reports·2017
Same author

Reduction of Slit Diaphragm-associated Molecules by Sirolimus: Is it Enough to Induce Proteinuria?

Transplantation proceedings·2017
Same journal

Theoretical Foundations of the Echo Envelope Statistical Modeling: A Tutorial.

IEEE transactions on ultrasonics, ferroelectrics, and frequency control·2025
Same journal

Practical Demonstrations of FR3-Band Thin-Film Lithium Niobate Acoustic Filter Design.

IEEE transactions on ultrasonics, ferroelectrics, and frequency control·2025
Same journal

Real-Time Heterogeneous Helical Wave Spectrum Method for Transabdominal Passive Acoustic Mapping.

IEEE transactions on ultrasonics, ferroelectrics, and frequency control·2025
Same journal

Cascaded Plane Wave Ultrasound Velocity Vector Imaging: In Vivo Feasibility in Carotid Arteries.

IEEE transactions on ultrasonics, ferroelectrics, and frequency control·2025
Same journal

Quantitative Acoustic Attenuation Scanning Using a Phase-Insensitive Ultrasound Computed Tomography System.

IEEE transactions on ultrasonics, ferroelectrics, and frequency control·2025
Same journal

FPGA-Accelerated CNN Reconstruction for Low-Power Sparse-Array Ultrasound Imaging.

IEEE transactions on ultrasonics, ferroelectrics, and frequency control·2025
See all related articles

Related Experiment Video

Updated: Jul 7, 2026

Fibroblast Derived Human Engineered Connective Tissue for Screening Applications
09:50

Fibroblast Derived Human Engineered Connective Tissue for Screening Applications

Published on: August 20, 2021

High-resolution elasticity imaging for tissue engineering.

N Abraham Cohn1, B S Kim, R Q Erkamp

  • 1Dept. of Biomed. Eng. and Electr. Eng., Michigan Univ., Ann Arbor, MI, USA.

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
|February 2, 2008
PubMed
Summary
This summary is machine-generated.

An elasticity microscope images tissue elasticity with high resolution. This tool shows promise for monitoring tissue engineering, accurately depicting cell layers and embedded structures.

More Related Videos

Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth
12:18

Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth

Published on: February 9, 2012

Postproduction Processing of Electrospun Fibres for Tissue Engineering
15:52

Postproduction Processing of Electrospun Fibres for Tissue Engineering

Published on: August 9, 2012

Related Experiment Videos

Last Updated: Jul 7, 2026

Fibroblast Derived Human Engineered Connective Tissue for Screening Applications
09:50

Fibroblast Derived Human Engineered Connective Tissue for Screening Applications

Published on: August 20, 2021

Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth
12:18

Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth

Published on: February 9, 2012

Postproduction Processing of Electrospun Fibres for Tissue Engineering
15:52

Postproduction Processing of Electrospun Fibres for Tissue Engineering

Published on: August 9, 2012

Area of Science:

  • Biomedical Engineering
  • Materials Science

Background:

  • Tissue engineering requires methods to monitor cell growth and tissue development.
  • High-resolution imaging of tissue elasticity is crucial for understanding tissue mechanics.

Purpose of the Study:

  • To evaluate the utility of an elasticity microscope for monitoring tissue engineering applications.
  • To assess the capability of the microscope in imaging elastic properties of different tissue models.

Main Methods:

  • Elasticity micrographs were acquired from two distinct tissue engineering model systems.
  • Strain images and reconstructed elasticity images were analyzed to assess elastic properties.
  • The performance of a one-dimensional mechanical model was compared to more complex scenarios.

Main Results:

  • The elasticity microscope clearly distinguished a cell layer from its matrix in a smooth muscle tissue model using strain images alone.
  • In a more complex model with embedded microspheres, reconstructed elasticity images were necessary to differentiate structures.
  • High spatial resolution (75 micrometers or less) was achieved in imaging elastic properties.

Conclusions:

  • The elasticity microscope is a valuable tool for high-resolution imaging of soft tissue elastic properties.
  • It shows significant potential for applications in tissue engineering, including monitoring cell growth and tissue development.
  • The instrument's ability to differentiate structures based on elasticity is key to its utility.