Power Doppler sonography: anything to add to BI-RADS US in solid breast masses?
Gokhan Gokalp1, Ugur Topal, Esref Kizilkaya
1Department of Radiology, Uludag University Medical Faculty, 16059 Gorukle, Bursa, Turkey. drgokhangokalp@yahoo.com
Objective:
To evaluate the contribution of power Doppler ultrasonography (PDUS) to breast imaging reporting and data system ultrasonography (BI-RADS US) categorization of solid breast masses.
Materials And Methods:
Totally 94 solid lesions with histopathological results in 49 patients were included in the study. US features of the lesions were classified according to American College of Radiologists (ACR) BI-RADS US lexicon. Lesions were evaluated qualitatively according to their PDUS properties and quantitatively with spectral analysis. Hypervascularity, penetration of vessels into the mass or branching-disordered course and resistivity index values higher than 0.85 were accepted as probable malignant criteria.
Results:
Fifty-five of 94 lesions were benign (58.5%), while 39 (41.5%) were malignant histopathologically. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of US and PDUS in the diagnosis of malignant lesions were 100%, 58.2%, 62.9%, 100% and 71.8%, 81.8%, 73.7%, 80.4%, respectively. Criteria used for the distinction of malignant and benign lesions like number of vessels (p<0.05), distribution of tumoral vessels, morphology of vessels and resistivity index values higher than 0.85 showed statistically significant difference (p<0.001). When sonographic findings were combined with PDUS and spectral analysis findings, sensitivity, specificity, PPV and NPV were 100%, 52.7%, 60% and 100%, respectively.
Conclusion:
PDUS and spectral analysis have no contribution to BI-RADS US. For the spectral analysis, when RI value is one or greater, malignancy risk significantly increases.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies II: Ultrasonography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):