Related Experiment Video
Updated: Jul 7, 2026

The Diffusion of Passive Tracers in Laminar Shear Flow
Published on: May 1, 2018
Speckle decorrelation due to two-dimensional flow gradients
B H Friemel1, L N Bohs, K R Nightingale
1Ultrasound Group, Siemens Med. Syst., WA.
Abstract:
The performance of ultrasonic velocity estimation methods is degraded by speckle decorrelation, the change in received echoes over time. Because ultrasonic speckle is formed by the complex sum of echoes from subresolution scatterers, it is sensitive to the relative motion of those scatterers. Velocity gradients in flowing blood result in relative scatterer motion and can be a significant source of speckle decorrelation. Computer simulations were performed to evaluate speckle decorrelation due to two-dimensional flow gradients. Results indicate that decorrelation due to flow gradients is sensitive to the angle of flow and has a maximum at a beam-vessel angle of 0 degrees , i.e., purely axial flow. A quantitative summary of the major factors causing speckle decorrelation indicates that flow gradients are the most significant contributors under the conditions modeled.
Related Concept Videos
Uniform Depth Channel Flow
Uniform Depth Channel Flow: Problem Solving
Gradually Varying Flow
Rapidly Varying Flow
Bernoulli's Equation for Flow Along a Streamline
Steady Flow of a Fluid Stream
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...