Related Experiment Video
Updated: Jul 6, 2026

Ultrasound Velocity Measurement in a Liquid Metal Electrode
Published on: August 5, 2015
Statistical error analysis of time and polarization resolved ultrasonic measurements
D Xiang1, N N Hsu, G V Blessing
1Div. of Autom. Production Technol., Nat. Inst. of Stand. and Technol., Gaithersburg, MD.
Abstract:
The time and polarization resolved ultrasonic technique which we previously developed has been demonstrated to simultaneously provide measurements of the wave velocity in the coupling liquid, and the leaky surface wave and leaky longitudinal wave velocities in solid samples. To document the measurement precision associated with this technique, a statistical method is employed for the data fit and error analysis. With the help of statistical analysis, the simple ray model used to determine wave velocities in this technique is first confirmed by theoretical data which are predicted by the Green's function. Error analysis is then applied to the experimental data. The results show that this technique has a relative expanded uncertainty (equal to twice the standard deviation) of 0.03% for the wave velocity in water, and an uncertainty less than 0.2% and 2%, respectively, for the leaky surface and leaky longitudinal wave velocities in a crown glass sample. The uncertainty in the repeatability for leaky surface wave measurements is observed to be much less than the expanded uncertainty of a single measurement set. This methodology also has been applied to a set of steel samples. The results allow that the expanded uncertainty for leaky surface wave velocities is less than 0.07%, enabling a correlation of the measured velocities with specific sample heat treatments.
More Related Videos
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
09:02Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Uncertainty in Measurement: Reading Instruments
NMR Spectrometers: Resolution and Error Correction
Statistical Analysis: Overview
One of the most commonly used statistical quantifiers is the mean, which is the ratio between the sum of the numerical values of all results and the...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...