A Silicon-tipped Fiber-optic Sensing Platform with High Resolution and Fast Response
Published on: January 7, 2019
Reflection intensity optical fiber sensors for the mid-infrared
Applied Optics
|February 20, 1997
Summary
Two new mid-infrared reflection sensors using chalcogenide glass fiber were developed. A single-fiber sensor achieved nearly 50% of the sensitivity of a double-fiber sensor for spectral measurements.
Area of Science:
- Optical sensing technologies
- Mid-infrared spectroscopy
- Materials science
Background:
- Chalcogenide glass fibers offer unique properties for mid-infrared (mid-IR) applications.
- Reflection intensity sensors are crucial for non-destructive material analysis.
- Existing sensor designs may have limitations in sensitivity or complexity.
Purpose of the Study:
- To demonstrate two novel reflection intensity sensors for the mid-IR region.
- To evaluate the performance of single-fiber and double-fiber sensor configurations.
- To develop a theoretical model for sensor characterization.
Main Methods:
- Fabrication of double-fiber and single-fiber reflection sensors using chalcogenide glass fiber.
- Integration of sensors with a Fourier-transform infrared (FTIR) spectrometer using nonimaging concentrators.
- Measurement of absorption spectra for polymer coatings and paper.
- Development and application of a theoretical model for signal-to-background ratio analysis.
Main Results:
- Demonstration of two distinct reflection sensor designs: a double-fiber sensor with a waveguide and a single-fiber sensor with contact couplers.
- Successful coupling of sensors to an FTIR spectrometer for spectral measurements.
- Application of a theoretical model to derive sensor sensitivity from experimental data.
- The single-fiber reflection sensor with a symmetric coupler exhibited approximately 50% of the absorption peak heights compared to the double-fiber sensor.
Conclusions:
- Both developed reflection sensors are viable for mid-IR spectral measurements.
- The single-fiber sensor offers a potentially simpler alternative, though with reduced sensitivity compared to the double-fiber design.
- The theoretical model effectively aids in understanding and quantifying sensor performance characteristics.
Related Concept Videos
Infrared (IR) Spectroscopy: Overview
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
IR Spectrometers
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
IR Spectrum
When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
Total Internal Reflection Fluorescence Microscopy
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
IR Frequency Region: Fingerprint Region
IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the C=O, C=N, and C=C occur between 1600–1850 cm−1.
The...
The...
IR Spectrum Peak Intensity: Amount of IR-Active Bonds
When infrared radiation is passed through a molecule, absorption occurs if the molecule's vibration leads to a substantial change in its bond dipole moment. Transitions between vibrational energy levels, typically corresponding to infrared frequencies (4000–400 cm−1), allow absorption if the vibration significantly alters the dipole moment, making the molecule infrared active. The molecular bonds have different stretching and bending vibrations, resulting in various peaks with varying...