Contrast limits of coherence-gated imaging in scattering media
Abstract:
The fundamental difference between time-resolved and coherence-gated imaging modalities in scattering media is analyzed in terms of their optical transfer functions. The effectiveness of coherence gating for multiple-scattering rejection is shown by imaging a 100-mum-thick razor blade hidden in the scattering phantoms (i.e., Intralipid suspensions) with different scattering coefficients. We found that the imaging contrast is limited by multiple scattering and speckle effects in high-scattering media, and the measured effective penetration depth of optical coherence tomography is approximately equal to six mean free paths under the experimental conditions of a numerical aperture of less than 0.1 and a scattering anisotropy of approximately 0.8.
More Related Videos
12:54Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
05:59New Framework for Understanding Cross-Brain Coherence in Functional Near-Infrared Spectroscopy (fNIRS) Hyperscanning Studies
Published on: October 6, 2023
Related Concept Videos
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...