Related Experiment Video
Updated: Jul 7, 2026

An Automated Microscopic Scoring Method for the γ-H2AX Foci Assay in Human Peripheral Blood Lymphocytes
Published on: December 25, 2021
Population exposure to ionizing radiation from medical examinations in France
P Scanff1, J Donadieu, P Pirard
1Institut de Radioprotection et de Sûreté Nucléaire, Unité d'Expertise en Radioprotection Médicale, BP 17, 92 262 Fontenay aux Roses, France. pascale.scanff@irsn.fr
Abstract:
This study was carried out to update data concerning both the nature and the frequency of X-ray diagnostic procedures and to reassess the associated per caput effective dose in France, given that the only nationwide survey was carried out over 15 years ago. Relevant data concerning examinations in conventional radiology, computed tomography, interventional radiology and nuclear medicine were obtained for the year 2002 from two main sources: the main health insurance records for private practices and the statistics of healthcare establishments on hospital activity. Doses associated with different types of examination were obtained from the diagnostic reference levels (DRL) campaign, together with data from the European Commission and from the Health Protection Agency in the UK. The results show that between 55.4 and 65.9 million procedures were performed in 2002 in conventional radiology (one-third for dental) and between 4.2 and 6 million in computed tomography. There were 850,000 and 900,000 procedures in nuclear medicine and interventional radiology respectively. Conventional radiology accounts for 90% of the total number of procedures but only 37% of the collective dose, whereas examinations in computed tomography account for 8% of total examinations but 39% of the collective dose. Examinations in nuclear medicine and interventional radiology account for 2% of procedures but 7% and 17% of the collective dose respectively. Finally, the per caput effective dose in 2002 was between 0.66 and 0.83 mSv.
Related Concept Videos
Biological Effects of Radiation
X-ray Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT

