Related Experiment Video
Updated: Jul 7, 2026

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
Published on: February 20, 2021
Radiochromic film for verification of superficial x-ray backscatter factors
M J Butson1, T Cheung, P K N Yu
1City University of Hong Kong, Department of Physics and Materials Science, Kowloon Tong, Hong Kong. martin.butson@sesiahs.health.nsw.gov.au
Abstract:
Accurate calculation and knowledge of backscatter factors (BSF) in superficial x-ray radiotherapy is required to perform accurate absorbed dose determination. These measurements have been performed historically with small thin parallel plate ionisation chambers and Thermoluminescent Dosimeters (TLD's). This note investigates the use of a low energy dependence radiochromic thin film (GAFCHROMIC EBT) for measurement and verification of backscatter factors. A single layer film and an extrapolation method with multiple films have been investigated. 50kVp to 150kVp beams were analysed and results for BSF were measured and compared to IPEMB (Institution of Physics and Engineering in Medicine and Biology UK) derived results. Agreement within 2% (1 SD) was found using both the single layer and extrapolation techniques with IPEMB derived results at 30cm SSD and equivalent photon energies. A 150kVp beam was found to have BSF of 1.12 +/- 0.02 (2cm circle), 1.24 +/- 0.01 (5cm circle), 1.36 +/- 0.02 (10cm circle) respectively compared to 1.11, 1.23 and 1.36 for IPEMB derived results. In summary a single layer film provided an accurate measurement and verification of BSF and was found to be within 2% of derived IPEMB results in all cases. The extrapolation method in general provided a slightly closer match to IPEMB results (<1%) but with no extra discernable accuracy than the single layer film most likely due to the already small thickness (0.3mm) of one film piece. GAFCHROMIC EBT, Radiochromic film provides a very simple and easy method for measurement and verification of BSF for x-ray energies commonly used for superficial x-ray therapy.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
Related Concept Videos
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...