Related Experiment Video
Updated: Jul 7, 2026

Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
Published on: June 29, 2013
Ductus venosus Doppler velocimetry in the first trimester: a new finding
L S Teixeira1, J Leite, M J B C Viegas
1Pós-Graduação em Saúde da Mulher, Faculdade de Medicina, Belo Horizonte, Minas Gerais, Brazil.
Objectives:
To establish reference curves for ductus venosus blood flow velocities during the first trimester and compare them with previously published curves.
Methods:
This was a cross-sectional and retrospective study performed between January 1998 and January 2003. The following inclusion criteria were used: singleton pregnancy, velocity measurements taken when the crown-rump length (CRL) was between 34 and 84 mm, absence of fetal anomalies, full-term pregnancy and newborn birth weight appropriate for gestational age. The following variables of the ductus venosus were measured: peak velocity during ventricular systole (S-wave) and diastole (D-wave), nadir during atrial contraction in late diastole (A-wave), time-averaged maximum velocity (TAMXV) and pulsatility index for veins (PIV).
Results:
A total of 843 fetuses were included. The mean CRL was 62 (range, 34-84) mm. The S-wave, D-wave, TAMXV and PIV were normally distributed, and logarithmic transformation was performed to achieve a normal distribution for the A-wave. S-wave, D-wave and A-wave and TAMXV increased with CRL. PIV increased up to a CRL of 63 mm and decreased thereafter. Regression analysis revealed a significant quadratic relationship between PIV and CRL.
Conclusions:
S-wave, D-wave, A-wave velocities and TAMXV in the ductus venosus increase with CRL between 34 and 84 mm. The reference range for PIV has a biphasic pattern, with an initial non-significant increase up to a CRL of 63 mm and a fall thereafter.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Development of Blood Vessels
The initial formation of this system is facilitated by the small amount of yolk present in the ovum and yolk sac. Blood vessels originate from...

