Related Experiment Video
Updated: Jul 7, 2026

Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
Whole-body imaging of oncologic patients using 16-channel PET-CT. Evaluation of an i.v. contrast enhanced MDCT
K U Juergens1, M L Oei, M Weckesser
1Department of Clinical Radiology, University of Muenster, Albert-Schweitzer-Strasse 33, 48149 Muenster, Germany. kujuerg@uni-muenster.de
Aim:
This study evaluated a MDCT protocol for contrast-enhanced 16-channel PET-CT with regard to scan range and duration of a whole-body (18)F-FDG PET-CT examination, the occurrence of contrast-material induced artefacts and quantitative assessment of CT attenuation.
Patients, Methods:
205 patients (51.9+/-12.4 years) with different malignant tumours underwent whole-body PET-CT; the study protocol had been approved by the institutional review board. Contrast-enhanced MDCT (16 x 1.5 mm; 120 ml Iomeprol 3 ml/s, 50 ml saline chaser bolus, scan delay 70 s; oral contrast) was also used for attenuation correction. From MDCT data mean scan range and duration, occurrence of contrast media-induced artefacts, and mean CT densities of jugular (jv) and subclavian (scv), superior (vcs) and inferior (vci) caval, portal (pv), and bilateral external iliac veins, pulmonary (ap) and iliac arteries, descending thoracic and abdominal aorta, all cardiac chambers, as well as both liver lobes, spleen, adrenal glands and kidneys were determined.
Results:
Attenuation corrected PET images were free of contrast media-related image artefacts. Homogeneous contrast enhancement was found in the mediastinal veins (right/left jv 171+/-34/171+/-35, scv 127+/-50/127+/-40, vcs 153+/-36 HU) and arteries (e.g. ap 145+/-26/151+/-26). Cardiac chambers, abdominal vessels (e.g. vci 138+/-24, pv 159+/-25 HU), and parenchymal organs revealed sufficient and homogenous contrast-enhancement in all cases. No beam-hardening artefacts occurred in the neighbourhood of the subclavian veins.
Conclusion:
The chosen whole-body (18)F-FDG 16-slice PET-CT protocol allowed for craniocaudal CT scanning with high vessel and parenchymal contrast revealing no IV contrast-media induced artefacts in attenuation-corrected PET data sets.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...