A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Time-dependence of appropriate implantable defibrillator therapy in patients with ischemic cardiomyopathy
Alawi A Alsheikh-Ali1, Michael Homer, Prasad V Maddukuri
1Institute for Clinical Research and Health Policy Studies, New England Cardiac Arrhythmia Center, Department of Medicine, Tufts-New England Medical Center, Tufts University School of Medicine, Boston, Massachusetts 02111, USA. aalsheikh-ali@tufts-nemc.org
Insights
The risk of appropriate implantable cardioverter-defibrillator (ICD) therapy for ventricular arrhythmia is highest in the first year after implantation in primary prevention patients. This risk persists for up to seven years, indicating the need for ICD replacement.
Area of Science:
- Cardiology
- Electrophysiology
- Medical Devices
Background:
- Limited data exists on implantable cardioverter-defibrillator (ICD) therapy outside clinical trials.
- Routine practice patient follow-up and device replacement questions are critical.
- Understanding long-term outcomes in primary prevention is essential.
Purpose of the Study:
- To assess the incidence and time-dependence of appropriate ICD therapy.
- To evaluate outcomes in a primary prevention population with prior myocardial infarction (MI) and reduced left ventricular ejection fraction (LVEF).
- To inform clinical practice regarding device longevity and replacement strategies.
Main Methods:
- Retrospective analysis of 525 patients receiving ICDs for primary prevention (1995-2005).
- Inclusion criteria: prior MI and LVEF ≤35%.
- Determination of incidence and time-dependence of first appropriate ICD therapy for ventricular arrhythmia (VA) and rapid VA.
Main Results:
- 22% of patients (115/525) received appropriate ICD therapy.
- First appropriate ICD therapy incidence was 20% in year 1, decreasing to 12% in year 2, and 6-11% annually thereafter.
- A similar trend was observed for rapid VA, with a persistent risk up to year 7.
Conclusions:
- Appropriate ICD therapy incidence is highest in the first year post-implant for primary prevention patients.
- The risk of ventricular arrhythmia requiring ICD therapy persists for at least seven years.
- ICD replacement appears indicated for all patients due to persistent risk.
Introduction:
Little is known about the risk of appropriate implantable cardioverter-defibrillator (ICD) therapy outside the context of controlled clinical trials where routine practice patients are followed for longer durations and questions of device replacement frequently arise. We assessed the incidence and time-dependence of appropriate ICD therapy in a routine clinical practice primary prevention population with prior myocardial infarction (MI) and reduced left ventricular ejection fraction (LVEF).
Methods And Results:
Patients with prior MI and LVEF
Conclusion:
In a routine clinical practice primary prevention population with prior MI and LVEF
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy II: Dilated Cardiomyopathy
Dysrhythmias VI: Management of Dysrhythmias
Cardiomyopathy III: Hypertrophic Cardiomyopathy
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Antiarrhythmic Drugs: Class III Agents as Potassium Channel Blockers