Related Experiment Video
Updated: Jul 7, 2026

Design and Use of a Full Flow Sampling System (FFS) for the Quantification of Methane Emissions
Published on: June 12, 2016
High-rangeability ultrasonic gas flowmeter for monitoring flare gas
1Dept. of Sci. and Technol., Chr. Michelsen Inst., Fantoft.
Abstract:
A transit-time ultrasonic gas flowmeter for high-rangeability requirements, such as those encountered in flare-gas flow-metering, is presented. The concept of ray rescue angle for the orientation of the ultrasonic transducers in single-beam transit-time ultrasonic flowmeters is introduced to overcome the problem of ultrasonic beam drift in high-velocity flows. To overcome problems associated with noise at high velocities, a chirp signal is used. To preserve the accuracy of the meter at low velocities near zero flow, a combination of chirp and continuous-wave signals is used to interrogate the flow. Overall system performance is presented, based on results from extensive wind-tunnel tests.
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Flame Photometry: Overview
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
General External Flow Characteristics
Turbulent Flow: Problem Solving
Temperature is a key factor in CO2 solubility. In this case, the CO2 gas and the liquid are cooled to 20°C. Lower temperatures enhance...