Performance evaluation of a new small-volume coagulation monitor: the SmartCheck INR system
Chris Gardiner1, Ian Longair, Jennifer Hills
1Department of Haematology, University College London Hospitals, London, England.
Abstract:
The SmartCheck INR (Unipath, Bedford, England) is a point-of-care device for professional and patient self-monitoring of oral anticoagulant therapy. It measures the international normalized ratio (INR) and assesses test strip integrity, temperature, and sample quality. No significant differences were found in SmartCheck INR results from 3 different instruments or in 3 test-strip lots. Within run imprecision was 0.89% and 6.36% for low and high control samples, respectively (mean INR, 0.99 and 4.08, respectively). Comparability was assessed in 68 patients receiving warfarin by using PTHS Plus (Instrumentation Laboratory, Lexington, MA) and Innovin (Dade Behring, Marburg, Germany) thromboplastins. Good correlations were observed between the methods (r = 0.89 and r = 0.90, respectively) with no significant differences in means: SmartCheck INR, 2.82; Innovin, 2.75; PTHS Plus, 2.74. Clinical agreement with laboratory methods was 88% for Innovin and 97% for PTHS Plus. The SmartCheck INR was easy to use with no mechanical failures during the evaluation and a low test-strip failure rate of 4.7%. The SmartCheck INR provides accurate and reproducible results and is suitable for routine monitoring of oral anticoagulant therapy in the majority of patients.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: