Jove
Visualize
Contact Us

Related Concept Videos

Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Electronic Distance Measuring Instruments01:30

Electronic Distance Measuring Instruments

Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short distances...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Flame Photometry: Overview01:02

Flame Photometry: Overview

Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Wide-angle stray-light reduction for a spaceborne optical hemispherical imager.

Applied optics·2010
Same author

Improved design for stray-light reduction with a hemispherical imager.

Applied optics·2008
Same author

Sharpening stellar images.

Science (New York, N.Y.)·1978
See all related articles
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jul 7, 2026

Bringing the Visible Universe into Focus with Robo-AO
10:35

Bringing the Visible Universe into Focus with Robo-AO

Published on: February 12, 2013

Very-wide-angle optical systems suitable for spaceborne photometric measurements.

A Buffington

    Applied Optics
    |February 21, 2008
    PubMed
    Summary

    Observing the solar corona requires precise photometry, achieved by spreading images over many pixels with large format CCD cameras. This enables simple, wide-angle optical designs for spaceborne imaging.

    Area of Science:

    • Spaceborne optics
    • Solar physics
    • Instrument design

    Background:

    • Observing the solar corona requires high-precision photometry (0.1% differential broadband) over large angular extents.
    • Current CCD camera specifications necessitate spreading unresolved images across multiple pixels.

    Purpose of the Study:

    • To develop and validate optical design principles for spaceborne solar corona observation.
    • To enable simple, lightweight, very-wide-angle optical systems capable of imaging nearly the entire sky.

    Main Methods:

    • Formulating equations relating sky angle to focal-plane position.
    • Determining tangential and sagittal focal surfaces to govern CCD image size.
    • Conducting laboratory measurements with prototype optical configurations.

    More Related Videos

    Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures
    08:01

    Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures

    Published on: November 21, 2019

    Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)
    12:22

    Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)

    Published on: August 4, 2018

    Related Experiment Videos

    Last Updated: Jul 7, 2026

    Bringing the Visible Universe into Focus with Robo-AO
    10:35

    Bringing the Visible Universe into Focus with Robo-AO

    Published on: February 12, 2013

    Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures
    08:01

    Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures

    Published on: November 21, 2019

    Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)
    12:22

    Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)

    Published on: August 4, 2018

    Main Results:

    • Established relationships between sky angle and focal-plane position for wide-field imaging.
    • Characterized tangential and sagittal focal surfaces crucial for image quality.
    • Validated theoretical calculations through experimental measurements.

    Conclusions:

    • Large image formats on CCDs facilitate necessary photometric precision for solar corona studies.
    • The proposed optical design approach enables simplified, lightweight, and wide-angle systems for spaceborne applications.