Related Experiment Video
Updated: Jul 7, 2026

Fabrication and Operation of Acoustofluidic Devices Supporting Bulk Acoustic Standing Waves for Sheathless Focusing of Particles
Published on: March 6, 2016
The focusing of surface-acoustic-waves launched from a slanted chirped transducer. I. Isotropic substrate
M E Barnard1, M J Lancaster, E S Paige
1Dept. of Eng. Sci., Oxford Univ.
Abstract:
The focusing behavior of surface acoustic waves launched from a slanted chirped transducer (SCT) is explored using both a continuum model and a discrete model for sources associated with a linear FM chirp transducer on a substrate with isotropic properties. The continuum model leads to the prediction of an understanding of effects that would arise in the radiation field of an SCT on an isotropic substrate. It is based on a representation of the transducer as a continuum of sources, with the radiation field determined by applying the stationary phase method, and is presented for infinitesimally short fingers. It is compared with a more direct and exact but less revealing method of determining the field based on a discrete array of sources. The effects of increasing finger lengths are considered. The results are related to the focusing of radiation by a lens.