Related Experiment Video
Updated: Jul 7, 2026

Laparoscopic Repair of Para-Esophageal Hernia Using Absorbable Biosynthetic Mesh
Published on: September 11, 2021
Gastric full-thickness suturing during EMR and for treatment of gastric-wall defects (with video)
Daniel von Renteln1, Arthur Schmidt, Bettina Riecken
1Medizinische Klinik I, Klinikum Ludwigsburg, Ludwigsburg, Germany.
Background:
The endoscopic full-thickness Plicator device was initially developed to provide an endoscopic treatment option for patients with GERD. Because the endoscopic full-thickness Plicator enables rapid and easy placement of transmural sutures, comparable with surgical sutures, we used the Plicator device for endoscopic treatment or prevention of GI-wall defects.
Objective:
To describe the outcomes and complications of endoscopic full-thickness suturing during EMR and for the treatment of gastric-wall defects.
Design:
A report of 4 cases treated with the endoscopic full-thickness suturing between June 2006 and April 2007.
Setting:
A large tertiary-referral center.
Patients:
Four subjects received endoscopic full-thickness suturing. The subjects were women, with a mean age of 67 years.
Interventions:
Of the 4 subjects, 3 received endoscopic full-thickness suturing during or after an EMR. One subject received endoscopic full-thickness suturing for treatment of a fistula.
Main Outcome Measurements:
Primary outcome measurements were clinical procedural success and procedure-related adverse events.
Results:
The mean time for endoscopic full-thickness suturing was 15 minutes. In all cases, GI-wall patency was restored or ensured, and no procedure-related complications occurred. All subjects responded well to endoscopic full-thickness suturing.
Limitations:
The resection of one GI stromal tumor was incomplete. Because of the Plicator's 60F distal-end diameter, endoscopic full-thickness suturing could only be performed with the patient under midazolam and propofol sedation. The durable Plicator suture might compromise the endoscopic follow-up after EMR.
Conclusions:
The endoscopic full-thickness Plicator permits rapid and easy placement of transmural sutures and seems to be a safe and effective alternative to surgical intervention to restore GI-wall defects or to ensure GI-wall patency during EMR procedures.
Related Concept Videos
Peptic Ulcer Disease V: Surgical Management and Nursing Care
Surgical Interventions for Peptic Ulcer Disease
Endoscopic Procedures III: Video Capsule Endoscopy