Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Pipe Flowrate Measurement01:28

Pipe Flowrate Measurement

In pipe flow measurement, orifice, nozzle, and Venturi meters are commonly used to determine fluid flowrates by constricting the flow area, which increases fluid velocity and reduces pressure. This pressure difference, governed by Bernoulli's principle and adjusted for real-world conditions, is essential for calculating flowrate. Each meter type is suited to specific applications based on accuracy, efficiency, and compatibility with various flow conditions.
The orifice meter is a simple,...
Velocity and Acceleration in Steady and Unsteady Flow01:11

Velocity and Acceleration in Steady and Unsteady Flow

In fluid mechanics, velocity and acceleration are key concepts for analyzing particle motion in both steady and unsteady flow. Consider a fluid particle moving along a pathline, where its velocity depends on its position and time. The particle's acceleration is obtained by differentiating the velocity with respect to time.
The acceleration can be generalized to any point in the flow, and expressed as components along three perpendicular directions, representing changes in velocity over time.
Pipe Flowrate Measurement: Problem Solving01:28

Pipe Flowrate Measurement: Problem Solving

A spray tank system is engineered to uniformly distribute a pest-control liquid across plants by using a pressurized mechanism. The tank, pressurized to 150 kPa, holds the pesticide at a height of 0.80 meters. Liquid flows from the tank through a 1.9 meter pipe with a diameter of 0.015 meters, angled at 0.698 radians, ultimately reaching a 0.007 meter nozzle that sprays the pesticide. Accurate calculation of the system's flow rate is crucial to ensure uniform application, and this is achieved...
Velocity Potential01:20

Velocity Potential

In steady, incompressible flow through a long, straight pipe with a uniform cross-section, the flow in the central region (far from the pipe walls) is irrotational. This irrotational nature means that fluid particles do not rotate around their axes, and a scalar function called the velocity potential, represented by ϕ, can be used to describe their movement. In irrotational flows, the velocity field V is defined as the gradient of the velocity potential:
Rapidly Varying Flow01:24

Rapidly Varying Flow

Rapidly varying flow (RVF) in open channels is characterized by abrupt changes in flow depth over a short distance, with the rate of depth change relative to distance often approaching unity. These flows are inherently complex due to their transient and multi-dimensional nature, making exact analysis difficult. However, approximate solutions using simplified models provide valuable insights into their behavior.Key Features of Rapidly Varying FlowRVF is commonly observed in scenarios involving...
Bernoulli's Equation: Problem Solving01:16

Bernoulli's Equation: Problem Solving

A Venturi meter is essential for measuring fluid flow rates in pipelines. It utilizes the relationship between fluid velocity and pressure described by Bernoulli's equation. When installed in a sewage system, the Venturi meter accurately determines the wastewater flow rate by measuring pressure differences.
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity equation is...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A randomised controlled trial on the efficacy and tolerability with dose escalation of allopurinol 300-600 mg/day versus benzbromarone 100-200 mg/day in patients with gout.

Annals of the rheumatic diseases·2008
Same author

Efficacy and tolerability of urate-lowering drugs in gout: a randomised controlled trial of benzbromarone versus probenecid after failure of allopurinol.

Annals of the rheumatic diseases·2008
Same author

PSpice simulation of ultrasonic systems.

IEEE transactions on ultrasonics, ferroelectrics, and frequency control·2008
Same author

Thermostatic and dynamic performance of an ultrasonic density probe.

IEEE transactions on ultrasonics, ferroelectrics, and frequency control·2001

Related Experiment Video

Updated: Jul 7, 2026

High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
05:11

High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition

Published on: June 27, 2025

A new velocity algorithm for sing-around-type flow meters

J Delsing

    IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
    |January 1, 1987
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Visualization of Flow Field Around a Vibrating Pipeline Within an Equilibrium Scour Hole
    09:37

    Visualization of Flow Field Around a Vibrating Pipeline Within an Equilibrium Scour Hole

    Published on: August 26, 2019

    Investigating the Three-dimensional Flow Separation Induced by a Model Vocal Fold Polyp
    09:58

    Investigating the Three-dimensional Flow Separation Induced by a Model Vocal Fold Polyp

    Published on: February 3, 2014

    Related Experiment Videos

    Last Updated: Jul 7, 2026

    High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
    05:11

    High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition

    Published on: June 27, 2025

    Visualization of Flow Field Around a Vibrating Pipeline Within an Equilibrium Scour Hole
    09:37

    Visualization of Flow Field Around a Vibrating Pipeline Within an Equilibrium Scour Hole

    Published on: August 26, 2019

    Investigating the Three-dimensional Flow Separation Induced by a Model Vocal Fold Polyp
    09:58

    Investigating the Three-dimensional Flow Separation Induced by a Model Vocal Fold Polyp

    Published on: February 3, 2014