Cervical spine motion during tracheal intubation with manual in-line stabilization: direct laryngoscopy versus
Arnaud Robitaille1, Stephan R Williams, Marie-Hélène Tremblay
1Department of Anesthesiology, Centre Hospitalier de l'Université de Montréal, Hôpital Notre-Dame, 1560 Sherbrooke East, Montreal, Canada H2L 4M1.
Background:
The optimal tracheal intubation technique for patients with potential cervical (C) spine injury remains controversial. Using continuous cinefluoroscopy, we conducted a prospective study comparing C-spine movement during intubation using direct laryngoscopy (DL) or GlideScope videolaryngoscopy (GVL), with uninterrupted manual in-line stabilization of the head by an assistant.
Methods:
Twenty patients without C-spine pathology were studied. After induction of general anesthesia with neuromuscular blockade, both DL and GVL were performed on every patient in random order. Cinefluoroscopic images of C-spine movement during GVL and DL were acquired and divided into four stages: a baseline image before airway manipulation, glottic visualization, insertion of the endotracheal tube into the glottis, and tracheal intubation. Peak segmental motion from the occiput to C5 was measured offline for each patient and each stage, averages were calculated, and movements induced by each instrument were compared using a two-way ANOVA. Also studied were the proportion of patients with occiput-C1 rotation exceeding 10, 15, or 20 degrees, and the quality of glottic visualization.
Results:
No significant difference was found between DL and GVL regarding average segmental spine movement at any level (P values between 0.22 and 0.70). During both techniques, motion was mainly an extension concentrated in the rostral C-spine and occurred predominantly during glottic visualization. The proportion of patients with occiput-C1 extension of more than 10, 15, or 20 degrees was not significantly different. Glottic visualization was significantly better with GVL compared with DL.
Conclusion:
During intubation under general anesthesia with neuromuscular blockade and manual in-line stabilization, the use of GVL produced better glottic visualization, but did not significantly decrease movement of the nonpathologic C-spine when compared with DL.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Suctioning II: Procedure