Related Experiment Video
Updated: Jul 7, 2026

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Optic disc topography of normal Indian eyes: an assessment using optical coherence tomography
Shaun Dacosta1, Sheena Bilal, Babu Rajendran
1The Eye Research Foundation, Vijaya Hospital, Chennai - 600 026, India. shaundacosta@yahoo.com
Purpose:
To study the optic disc topographic measurements of normal Indian eyes using optical coherence tomography (OCT).
Materials And Methods:
One hundred and fifty eyes selected randomly from 150 normal Indian subjects of both sex and various age groups underwent optic disc imaging with the OCT using the fast optic disc protocol.
Results:
Mean +/- standard deviation of the optic disc topographic measurements were: disc area 2.63 +/- 0.55 mm 2 , cup area 0.87 +/- 0.45 mm 2 , neuroretinal rim area 1.78 +/- 0.55 mm 2 and cup to disc area ratio 0.33 +/- 0.15. There was no significant difference in the measurements between males and females. There was no significant correlation with respect to age and refractive errors ranging from -5.0 to +3.0 diopters of spherical equivalent.
Conclusion:
Our study provides a normative database for the various optic disc topographic measurements and its variations with age, sex and refractive error in normal Indian eyes using OCT.