Prioritized DCT for compression and progressive transmission of images

Y Huang1, H M Dreizen, N P Galatsanos

  • 1Dept. of Electr. and Comput. Eng., Illinois Inst. of Technol., Chicago, IL.

Related Concept Videos

Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Downsampling01:20

Downsampling

When considering a sampled sequence with zero values between sampling instants, one can replace it by taking every N-th value of the sequence. At these integer multiples of N, the original and sampled sequences coincide. This process, known as decimation, involves extracting every N-th sample from a sequence, thereby creating a more efficient sequence.
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Continuous -time Fourier Transform01:11

Continuous -time Fourier Transform

The Fourier series is instrumental in representing periodic functions, offering a powerful method to decompose such functions into a sum of sinusoids. This technique, however, necessitates modification when applied to nonperiodic functions. Consider a pulse-train waveform consisting of a series of rectangular pulses. When these pulses have a finite period, they can be accurately represented by a Fourier series. Yet, as the period approaches infinity, resulting in a single, isolated pulse, the...
Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next sampling...