Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Photon counting x-ray imaging with K-edge filtered x-rays: A simulation study.

Medical physics·2016
Same author

Dual energy CT with photon counting and dual source systems: comparative evaluation.

Physics in medicine and biology·2015
Same author

Permanent-magnet energy spectrometer for electron beams from radiotherapy accelerators.

Medical physics·2015
Same author

Soft tissue imaging with photon counting spectroscopic CT.

Physics in medicine and biology·2015
Same author

Photon counting spectral breast CT: effect of adaptive filtration on CT numbers, noise, and contrast to noise ratio.

Medical physics·2013
Same author

Dedicated phantom materials for spectral radiography and CT.

Physics in medicine and biology·2012
Same journal

Effective contrast-enhanced preprocessing for intracranial artery segmentation in digital subtraction angiography.

Physics in medicine and biology·2026
Same journal

Improving Plan Quality in Adaptive Proton Therapy Using an Interactive Dose Modification Tool.

Physics in medicine and biology·2026
Same journal

Technical Note: Real-Time MLC Control and Latency Measurement Optimization with External Verification.

Physics in medicine and biology·2026
Same journal

Fetus-Specific Hematopoietic Stem Cell Dosimetry Framework for Leukemia-Relevant Target Cells During Prenatal Development.

Physics in medicine and biology·2026
Same journal

Deep learning-based dose prediction to enhance planning efficiency in cervical brachytherapy with hybrid applicators.

Physics in medicine and biology·2026
Same journal

Corrigendum: Referenceless MR thermometry-a comparison of five methods (2017<i>Phys. Med. Biol</i>.<b>62</b>1-16).

Physics in medicine and biology·2026
See all related articles

Related Experiment Video

Updated: Jul 7, 2026

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
08:36

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner

Published on: June 7, 2024

Computed tomography with energy-resolved detection: a feasibility study.

Polad M Shikhaliev1

  • 1Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA, USA. pshikhal@lsu.edu

Physics in Medicine and Biology
|February 26, 2008
PubMed
Summary
This summary is machine-generated.

This study demonstrates that energy-resolved computed tomography (CT) using photon counting detectors significantly improves contrast-to-noise ratio (CNR) for breast imaging. The novel multi-slit multi-slice (MSMS) CT design enhances scatter rejection and image quality.

More Related Videos

Obtaining 3D Chemical Maps by Energy Filtered Transmission Electron Microscopy Tomography
08:15

Obtaining 3D Chemical Maps by Energy Filtered Transmission Electron Microscopy Tomography

Published on: June 9, 2018

Energy Dispersive X-ray Tomography for 3D Elemental Mapping of Individual Nanoparticles
10:00

Energy Dispersive X-ray Tomography for 3D Elemental Mapping of Individual Nanoparticles

Published on: July 5, 2016

Related Experiment Videos

Last Updated: Jul 7, 2026

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
08:36

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner

Published on: June 7, 2024

Obtaining 3D Chemical Maps by Energy Filtered Transmission Electron Microscopy Tomography
08:15

Obtaining 3D Chemical Maps by Energy Filtered Transmission Electron Microscopy Tomography

Published on: June 9, 2018

Energy Dispersive X-ray Tomography for 3D Elemental Mapping of Individual Nanoparticles
10:00

Energy Dispersive X-ray Tomography for 3D Elemental Mapping of Individual Nanoparticles

Published on: July 5, 2016

Area of Science:

  • Medical Physics
  • Radiological Imaging
  • Biomedical Engineering

Background:

  • Computed tomography (CT) is a vital diagnostic tool, but conventional methods face limitations in differentiating subtle tissue contrasts.
  • Energy-resolved x-ray detection offers potential for enhanced image quality and material differentiation in CT.
  • Multi-slit multi-slice (MSMS) CT configurations can improve data acquisition efficiency and scatter rejection.

Purpose of the Study:

  • To investigate the feasibility of energy-resolved breast CT using a multi-slit multi-slice (MSMS) design with photon counting detectors.
  • To evaluate the impact of photon energy weighting on contrast-to-noise ratio (CNR) for various contrast agents.
  • To assess the performance of a tilted Cadmium Zinc Telluride (CZT) detector for improved spectral characteristics.

Main Methods:

  • Simulations were performed using a digital breast phantom with varying compositions and contrast elements (carcinoma, iodine, CaCO3).
  • Photon counting, energy integrating, and photon energy weighting CT images were generated and compared.
  • Dual-energy subtraction images were created using a single CT scan at a fixed tube voltage (90 kVp).
  • Experiments with a tilted CZT detector were conducted to analyze its effect on the x-ray energy spectrum.

Main Results:

  • Photon energy weighting improved CNR by factors of 1.16-1.36 compared to conventional energy-integrating detectors.
  • Dual-energy subtracted images showed CNR improvements of 1.35 for CaCO3 and 1.33 for iodine.
  • Combined CNR improvements from scatter rejection and energy weighting ranged from 1.71 to 2.
  • A 20-degree tilted CZT detector reduced spectral tailing compared to a conventional detector.

Conclusions:

  • Energy-resolved MSMS CT with photon counting detectors is feasible for breast imaging.
  • Photon energy weighting and scatter rejection significantly enhance CNR, improving lesion detectability.
  • The tilted CZT detector shows promise for optimizing spectral measurements in CT.
  • This technology offers a unique combination of photon counting, energy weighting, scatter rejection, and single kVp dual-energy subtraction.