Accuracy of 16-row multislice computed tomographic angiography for assessment of small cerebral aneurysms
Wenhua Chen1, Jie Wang, Wei Xin
1Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China. chewenhua@tom.com
Objective:
Many cases of subarachnoid hemorrhage are the result of rupture of small cerebral aneurysms. The aim of the study was to assess the diagnostic accuracy of 16-row multislice computed tomographic angiography (CTA) in detecting small cerebral aneurysms (
Methods:
One hundred ninety-two consecutive patients underwent CTA for suspected cerebral aneurysms. All aneurysms prospectively detected by CTA were confirmed by DSA or surgery. This was performed with a 16-detector row machine, with a detector slice of 0.75 mm, reconstruction interval of 0.40 mm, and timing determined by bolus trigger. CTA and DSA images were reviewed by two independent, blinded neuroradiologists who performed aneurysm detection, quantitation, and characterization using maximum-intensity projections, shaded-surface display, and volume-rendering techniques reconstructions.
Results:
Combining CTA, DSA, and intraoperative findings, 64 small cerebral aneurysms (
Conclusion:
Noninvasive 16-slice CTA is sensitive enough to replace conventional DSA in the triage, diagnosis, and treatment planning in patients with small cerebral aneurysms.
Related Concept Videos
Aneurysm III: Interprofessional Care
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...