Related Experiment Video
Updated: Jul 7, 2026

Force System with Vertical V-Bends: A 3D In Vitro Assessment of Elastic and Rigid Rectangular Archwires
Published on: July 24, 2018
Biomechanics of a Distal Jet appliance. Theoretical considerations and in vitro analysis of force systems
Gero S M Kinzinger1, Peter R Diedrich
1Department of Orthodontics, University of Aachen RWTH, Aachen, Germany. gkinzinger@ukaachen.de
Objective:
To analyze the forces and moments acting in the first molar region, induced by the Distal Jet appliance for maxillary molar distalization.
Materials And Methods:
Over a working section of 3 mm with reactivation of the loaded spring systems, the force systems of three laboratory-fabricated appliances of identical design were analyzed with a 3D metering device.
Results:
The force systems registered in vitro exhibited complex biomechanics. Regular reactivation of the loaded coils resulted in consistent distalizing forces and uprighting moments, in forces and moments toward buccal as well as slightly intrusive forces, and mesial-inwardly rotating moments. In the sagittal dimension, the Distal Jet appliance allows almost translatory molar distalization. Accordingly, applying uprighting activation is not necessary for treatment. Because of the application of the force palatal to the center of resistance of the molars, the teeth experience undesired mesial-palatal and distal-facial rotation.
Conclusions:
The Distal Jet appliance allows almost translatory distal molar movement, and uprighting activation is not necessary for treatment. The force applied palatal to the center of resistance of the molars produces an undesired mesial-palatal and distal-facial rotation. Regular intraoral coil spring reactivation is needed.
Related Concept Videos
Three-Dimensional Force System
Static and Kinetic Frictional Force
However, if two systems are in contact and are stationary relative to one...
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Method of Joints: Problem Solving II
Simplification of a Force and Couple System: II
Machines: Problem Solving I
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...