Related Experiment Video
Updated: Jul 7, 2026

Automated HPLC Separation Using LC-Mate: An Integrated Repetitive Autosampler and Fraction Collector for Microscale Purification
Published on: February 27, 2026
[Separation and purification of flavonoids from chrysanthemum indicum with macroporous resin]
1Tongren Vocational Institute, Tongren 554300, China. yujiansheng@sohu.com
Objective:
A method for separation and purification of flavonoids from C. indicum with macroporous resin was studied.
Method:
By using C. indicum in Guizhou as the materials and with the content and recovery rate of flavonoids as indexes, the static and dynamic adsorption tests were employed to investigated effects and affective factors of separation and purification of flavonoids from C. indicum with macroporous resin.
Result:
Results show that the static adsorption capacity of AB-8 type resin was 114.65 mg x g(-1), the static elution ratio were 94.9%, the dynamic adsorption capacity of AB-8 type resin was 94.5 mg x g(-1), the recovery rate was more than 92.6% and the purity of flavonoids was more than 90%. AB-8 type resin is the best for separating and purificating C. indicum in flavonoids.
Conclusion:
The optimum conditions is AB-8 type macroporous resin, 70% alcohol as the eluant and 2 to approximately 3 times volume of the resin as the eluant volume, the ratio of flavonoids to the volume of the resin as 1:10.6, concentration of flavonoids of sample as 19.8 mg x mL(-1) and current velocity as 2 to approximately 3 mL x min(-1), pH value of sample as 4 to approximately 5. [Key words]' macroporous resin; Chrysanthemum indicum; flavonoids; separation; purification
Related Concept Videos
Affinity Chromatography
Principles Of Column Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
High-Performance Liquid Chromatography: Elution Process
Extraction: Advanced Methods
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...