Related Experiment Video
Updated: May 2, 2026

Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction
Published on: December 3, 2017
Wichita fusion nail for patients with failed total knee arthroplasty and active infection
Wael K Barsoum1, Christopher Hogg, Viktor Krebs
1Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH 44195, USA.
Abstract:
In the study reported here, we retrospectively evaluated short-term results of knee arthrodesis using the Wichita fusion nail (WFN) in patients with active infection. Clinical examinations, x-rays, time to union, knee pain after fusion, and ambulatory status were compared in 7 patients who received the WFN. Mean fusion rate was 86%, mean time to fusion was 9.8 months, and mean complication rate was 57%. Complication rates were high, but clinical outcomes were acceptable, supporting use of WFN as a reasonable way to salvage failed total knee arthroplasty in patients with active infection.