Fast tools for calculation of atomic charges well suited for drug design

D A Shulga1, A A Oliferenko, S A Pisarev

  • 1Institute of Physiologically Active Compounds of Russian Academy of Sciences, Chernogolovka, Russia.

Related Concept Videos

Structure-Activity Relationships and Drug Design01:28

Structure-Activity Relationships and Drug Design

Drug design is a dynamic field that involves discovering and developing new medications based on specific biological targets. This process heavily relies on structure-activity relationships (SAR) and quantitative structure-activity relationships (QSAR) to guide the design and optimization of efficient drugs.
SAR studies the intricate relationship between a drug's chemical structure and biological activity. It focuses on understanding how modifications to a drug's structure can influence its...
Calculations of Electric Potential II01:27

Calculations of Electric Potential II

An electric dipole is a system of two equal but opposite charges, separated by a fixed distance. This system is used to model many real-world systems, including atomic and molecular interactions. One of these systems is the water molecule, but only under certain circumstances. These circumstances are met inside a microwave oven, where electric fields with alternating directions make the water molecules change orientation. This vibration is equivalent to heat at the molecular level.
Consider a...
Formal Charges02:42

Formal Charges

In some cases, there are seemingly more than one valid Lewis structures for molecules and polyatomic ions. The concept of formal charges can be used to help predict the most appropriate Lewis structure when more than one reasonable structure exists.
The Equilibrium Binding Constant and Binding Strength02:18

The Equilibrium Binding Constant and Binding Strength

The equilibrium binding constant (Kb) quantifies the strength of a protein-ligand interaction. Kb can be calculated as follows when the reaction is at equilibrium:
Coulometry: Overview01:00

Coulometry: Overview

Coulometry is one of the rapid, most accurate, and precise analytical techniques that determine the quantity of an analyte by measuring the electrical charge needed for its complete electrolysis without using any analytical standards. The total charge passed during electrolysis correlates with the analyte amount by Faraday's laws of electrolysis. For accurate coulometric measurements, a charge equal to Faraday's constant multiplied by the number of electrons involved in the relevant...
Patch Clamp01:18

Patch Clamp

Many fundamental cell functions such as muscle contraction and nerve transmission rely on the electrical signals produced by the movement of positively and negatively charged ions across the cell membrane. One competent method to record current flowing across the whole cell or single ion channel is the patch-clamp technique.
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...