A review of five cardiology journals found that observer variability of measured variables was infrequently reported
Robert M Gow1, Nicholas J Barrowman, Lillian Lai
1Children's Hospital of Eastern Ontario Research Institute, 410 Smyth Road, Ottawa, Ontario, Canada K1H 8L1. rgow@cheo.on.ca
Objective:
To investigate the reporting of the analysis of interobserver and intra-observer variability within clinical research studies from five high-impact cardiology journals published in 2005.
Study Design And Setting:
A cross-sectional study using a combined electronic and manual search identified 180 of 511 eligible articles that reported the assessment of observer variability. Sixty of these were randomly selected for detailed review.
Results:
The proportion of the 60 studies reporting interobserver variability, intra-observer variability, or both were 27%, 17%, and 53%, respectively. The reported methodological design of interobserver and intra-observer analyses included a specific protocol in 42% and 33%, identified observers as independent in 31% and 17%, as blinded in 50% and 31%, and identified a prior statistical plan in only 33% and 36%, respectively. Pearson correlation was the most reported measure for continuous variables, and the methods of Bland and Altman were reported in 15% of interobserver and 14% of intra-observer studies, respectively. For categorical variables, a kappa statistic was reported in 82% and 80%, respectively.
Conclusion:
Reliability assessment is hampered by unclear and incomplete reporting of interobserver and intra-observer analysis. For continuous variables, inappropriate methods were most frequently reported as being done.
Related Concept Videos
Bias in Epidemiological Studies
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Confounding in Epidemiological Studies
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Errors occurring during blood pressure monitoring
Several factors...
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and empty blood into the...