Matching from H(-) multicusp source to central region of a 100 MeV compact cyclotron for high current injection
Hongjuan Yao1, Tianjue Zhang, Yinlong Lu
1China Institute of Atomic Energy, Beijing, PR China. yhj03@mails.tsinghua.edu.cn
Abstract:
The way of matching the beam from an external ion source to the central region of the cyclotron CYCIAE-100 is presented in this article. The transverse acceptances of the central region were calculated, which provided the matching ellipse parameter requirements to the injection transport optics design. The optics of the injection line was simulated using TRANSOPTR, which allowed space charge effect calculation, and neutralization was taken into account.