Related Experiment Video
Updated: Jul 7, 2026

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Breath-by-breath measurement of oxygen using a compact optical sensor
Conor S Burke1, John P Moore, Dorota Wencel
1Dublin City University, National Centre for Sensor Research, Optical Sensors Laboratory, Glasnevin, Dublin 9, Ireland. conor. burke@dcu.ie
Abstract:
We report on the development of a novel optical oxygen sensor for breath monitoring applications using the technique of phase fluorometry. The principal design criteria are that the system be compact, lightweight, and employ a disposable sensing element (while performing competitively with current commercial analyzers). The oxygen-sensitive, luminescent ruthenium complex Ru[dpp](3)(2+) is encapsulated in a sol-gel matrix and deposited onto a custom-designed, polymer sensor chip that provides significantly improved luminescence capture efficiency. The performance of the sensor module is characterized using a commercially available lung simulator. A resolution of 0.03% O(2) is achieved, which compares well with commercial breath monitoring systems and, when combined with its immunity to humidity and ability to respond effectively across a broad range of breathing rates, makes this device an extremely promising candidate for the development of a practical, low-cost biodiagnostic tool.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...