Background:
Many surgical procedures are complicated by adhesions. These restrictive fibrotic bands form between normally separate gliding tissue layers, potentially impairing function. The authors tested the adhesion-modifying effect of a novel fibronectin-derived biomimetic biomaterial in a tendon-synovial complex injury model.
Methods:
The deep flexor tendons of digits 2 and 4 in the right forepaw of 15 New Zealand White rabbits were subjected to 5-mm-long partial tenotomies. Animals were randomized to receive biomaterial tubes enveloping the tendon injuries or left untreated. Digits, amputated at 2 weeks, were randomized to mechanical pullout assessments of adhesion strength or to quantitative histologic cellularity and immunohistochemical proliferation (Ki67) assessments.
Results:
The mean peak pullout force required to break the adhesions was reduced from 7.70 N (n = 6) in untreated digits to 0.31 N (n = 7) in biomaterial-treated digits (p = 0.001). The mean structural stiffness of the adhesions was also significantly reduced (p = 0.001). Histologically, treated and untreated digits demonstrated an equal incidence of adhesions. The treated adhesions were 55 percent less cellular at their surface than the untreated injured controls (p = 0.003). Treated tendons were 8 percent more cellular (with equal numbers of proliferating cells) at their surface and significantly more cellular within their bulk than positive controls (p
Conclusion:
This study suggests a significant reduction in the restrictive nature of postsurgical adhesions following treatment with the antiadhesive biomaterial without compromising tendon cellularity.