Related Experiment Video
Updated: Jul 6, 2026

A Technical Guide for Performing Spectroscopic Measurements on Metal-Organic Frameworks
Published on: April 28, 2023
Partitioning in situ total spectral absorption by use of moored spectral absorption-attenuation meters
1Ocean Physics Laboratory, University of California at Santa Barbara, 6487 Calle Real Unit A, Goleta, California 93177, USA. grace@icess.ucsb.edu
Abstract:
High-temporal-resolution spectral absorption data were acquired by use of one bottom-mounted (approximately 68-m) and three moored spectral absorption and attenuation meters (ac-9 meters at 14, 37, and 52 m) on the Middle Atlantic Bight continental shelf during the fall 1996 period of the Coastal Mixing and Optics experiment. We employed a previously published spectral absorption model with the data to partition total absorption into absorption by water, phytoplankton, detritus, and gelbstoff (dissolved matter). We validated the model by comparing its results against coincident in vivo absorption coefficients derived from discrete bottle samples. Correlations between modeled and in vivo spectra range from 0.873 to 0.998. We optimized these correlations to determine the model parameters. These parameters could not be determined solely from the moored ac-9 results. Therefore a separate set of absorption measurements (from discrete bottle samples) was necessary to permit values for the model parameters to be determined. Model results allow us to separate particulate and dissolved components of absorption and to examine the temporal variability and the vertical distributions and concentrations of each component, given the total absorption in the water column.
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
UV–Vis Spectrometers
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...

