Related Experiment Video
Updated: Jul 6, 2026

An Ivor Lewis Esophagectomy Designed to Minimize Anastomotic Complications and Optimize Conduit Function
Published on: April 17, 2020
Endoscopic full-thickness plication (Plicator) with two serially placed implants improves esophagitis and reduces PPI
D von Renteln1, U Brey, B Riecken
1Medizinische Klinik I, Klinikum Ludwigsburg, Ludwigsburg, Germany.
Background And Study Aims:
Recently, several endoluminal procedures for the treatment of gastroesophageal reflux disease (GERD) have been introduced. Most of these techniques have been abandoned because they lack long-term efficacy or have serious side effects. In a recently published prospective randomized, sham-controlled trial, the Plicator was shown to be effective at controlling reflux symptoms and esophageal acid exposure. In all previous studies, only a single implant was used. The aim of the present pilot study was to determine the safety and efficacy of two serially placed Plicator implants.
Patients And Methods:
Thirty-seven patients requiring maintenance therapy with proton pump inhibitors (PPIs) were enrolled in this single-center pilot study. All patients received two Plicator implants. Exclusion criteria were hiatus hernia larger than 3 cm, grade IV esophagitis, Barrett's esophagus, and esophageal motility disorders. The primary study end point was at least 50 % improvement in the GERD Health-Related Quality of Life (HRQL) score. Secondary end points included GERD medication use, esophageal acid exposure, esophagitis grade, and heartburn/regurgitation scores.
Results:
Thirty-seven patients underwent endoscopic full-thickness plication using two serially placed Plicator implants. At 6 months after treatment, the proportion of patients achieving at least 50 % improvement in GERD-HRQL score was 68 %. Complete cessation of PPI treatment was achieved in 59 % of patients. In pH studies conducted at 6 months (n = 29), median percentage of time for which pH was below 4 decreased by 36 %, with 28 % of patients experiencing pH normalization. There were no serious adverse events requiring intervention.
Conclusions:
Endoscopic full-thickness plication using two serially placed Plicator implants was both safe and effective in reducing esophagitis, GERD symptoms, medication use, and esophageal acid exposure.
More Related Videos
05:57ADSC-sheet Transplantation to Prevent Stricture after Extended Esophageal Endoscopic Submucosal Dissection
Published on: February 10, 2017
04:08Evaluation of the Effectiveness of Longitudinal Incision for Endoscopic Submucosal Excavation of Gastric Subepithelial Lesions
Published on: April 28, 2026
Related Concept Videos
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...
Gastroesophageal Reflux Disease II: Clinical Features and Management
Clinical Manifestations
GERD presents itself in a multitude of ways, with symptoms varying from person to person. The hallmark symptoms are...
Barrett Esophagus-II: Clinical Manifestations and Management
To diagnose Barrett's esophagus, healthcare providers often recommend an endoscopy for those showing symptoms of acid reflux. The procedure entails...
Esophageal Strictures-I: Introduction
Etiology
The primary cause of esophageal strictures is long-standing gastroesophageal reflux disease (GERD), accounting for about 70 to 80% of adult cases. Chronic acid reflux can lead to injury and scarring of the esophageal lining, culminating in...
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to: