Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique
Published on: May 15, 2013
Flex: a new computerized system for mechanical ventilation
Fleur T Tehrani1, James H Roum
1Department of Electrical Engineering, California State University, Fullerton, CA, USA. ftehrani@fullerton.edu
Objective:
To describe and evaluate a new weaning and decision support system for mechanical ventilation.
Background:
FLEX is a computerized weaning and decision support system for mechanical ventilation that unlike previous rule-based systems derives many of its rules on the basis of the conditions of individual patients. This system can be used in a wide range of ventilatory modes as well as automatic control of weaning. It incorporates the features of the patented ventilatory mode known as Adaptive Support Ventilation (ASV) along with other new features for control of weaning, and control of patient's oxygenation by adjustment of PEEP and the fraction of inspired oxygen.
Methods:
Ventilator data was collected for 10 patients in medical/surgical ICU at baseline and about 24 hours later. Required data fields for each patient for these two time points were also entered into the FLEX program. Comparison of clinical data and FLEX recommendations were made with regard to minute ventilation, alarms, weaning institution and other variables.
Results:
At baseline, 7 patients were being treated with AC, the remainder with IMV/PS. There was good agreement between the measured and recommended minute ventilations; variances were seen in some patients being treated with permissive hypercapnea and those with evidence of high oxygen needs or other metabolic derangements. At 24 hours, there was improved correlation between measured minute ventilation and that recommended by FLEX, suggesting that clinical adjustments were in-line with Flex recommendations over time. Furthermore, FLEX made recommendations with regard to FIO(2) and PEEP that would potentially diminish the risk of oxygen toxicity, hypoxemia, and barotrauma in selected patients. FLEX has also been implemented as a closed loop system in an initial set up.
Conclusion:
A new weaning and decision support system for mechanical ventilation is presented. The recommendations made by the system were found to be in line with clinical determinations. Further refinements in the FLEX predictions can be easily made by including inputs which represent permissive hypercapnea or increased metabolic demand for selected patients.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...