Imaging of angiogenesis using Cadence contrast pulse sequencing and targeted contrast agents
Susanne M Stieger1, Paul A Dayton, Mark A Borden
1Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, California, USA.
Objectives:
Low-power multipulse contrast ultrasound imaging provides a promising tool to quantify angiogenesis noninvasively when used with contrast agents targeted to vascular markers expressed by the angiogenic endothelium. Targeted ultrasound contrast agents, with a diameter on the order of micrometers, cannot extravasate and therefore are targeted solely to receptors expressed by the vascular endothelium. The aim of this study was to evaluate the potential of a low-power multipulse imaging sequence, Cadence(TM) contrast pulse sequencing (CPS), combined with targeted contrast agents to quantify angiogenesis.
Material And Methods:
Targeted microbubbles were prepared by conjugating echistatin via biotin-avidin linkage to the surface of a phospholipid microbubble shell. The density of echistatin present on the shell was confirmed with flow-cytometry and quantified by total fluorescence. The binding of targeted microbubbles was evaluated in vitro by quantifying the adherence of targeted microbubbles to rat aortic endothelial cells, compared with control (nontargeted) microbubbles. The circulation time and adherence of targeted microbubbles was evaluated in vivo in a Matrigel model in rats and compared with control microbubbles using CPS in addition to a destructive ultrasound pulse.
Results:
Using only the low-power CPS pulse, the echo intensity produced in the neovasculature of the Matrigel pellet was significantly greater with targeted microbubbles than with the control contrast agent (p < 0.001). Combining CPS with the destructive pulse, the processed image was significantly different in intensity (p < 0.001) and spatial extent between targeted and control agents (p < 0.001). When the morphology of the histological sample and ultrasound image correlated, the microvessel density count and the percentage of the circular area enhanced by ultrasound were correlated (p < 0.05).
Conclusion:
Low-power multipulse imaging in combination with targeted echistatin-bearing microbubbles facilitated a noninvasive, quantitative evaluation of early angiogenesis during real-time imaging. The addition of high-intensity destructive pulses facilitated estimation of the spatial extent of angiogenesis.
More Related Videos
05:08In vivo Imaging of Tumor Angiogenesis using Fluorescence Confocal Videomicroscopy
Published on: September 11, 2013
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies VII: Vascular Imaging
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System IV: CMRI