Related Experiment Video
Updated: Jul 6, 2026

Retroductal Submandibular Gland Instillation and Localized Fractionated Irradiation in a Rat Model of Salivary Hypofunction
Published on: April 24, 2016
Dose-effect relationships for the submandibular salivary glands and implications for their sparing by intensity
Carol-Anne Murdoch-Kinch1, Hyugnjin M Kim, Karen A Vineberg
1Department of Oral Medicine/Hospital Dentistry, University of Michigan, Ann Arbor, MI 48109-0010, USA.
Purpose:
Submandibular salivary glands (SMGs) dysfunction contributes to xerostomia after radiotherapy (RT) of head-and-neck (HN) cancer. We assessed SMG dose-response relationships and their implications for sparing these glands by intensity-modulated radiotherapy (IMRT).
Methods And Materials:
A total of 148 HN cancer patients underwent unstimulated and stimulated SMG salivary flow rate measurements selectively from Wharton's duct orifices, before RT and periodically through 24 months after RT. Correlations of flow rates and mean SMG doses were modeled throughout all time points. IMRT replanning in 8 patients whose contralateral level I was not a target incorporated the results in a new cost function aiming to spare contralateral SMGs.
Results:
Stimulated SMG flow rates decreased exponentially by (1.2%)(Gy) as mean doses increased up to 39 Gy threshold, and then plateaued near zero. At mean doses < or =39 Gy, but not higher, flow rates recovered over time at 2.2%/month. Similarly, the unstimulated salivary flow rates decreased exponentially by (3%)(Gy) as mean dose increased and recovered over time if mean dose was <39 Gy. IMRT replanning reduced mean contralateral SMG dose by average 12 Gy, achieving < or =39 Gy in 5 of 8 patients, without target underdosing, increasing the mean doses to the parotid glands and swallowing structures by average 2-3 Gy.
Conclusions:
SMG salivary flow rates depended on mean dose with recovery over time up to a threshold of 39 Gy. Substantial SMG dose reduction to below this threshold and without target underdosing is feasible in some patients, at the expense of modestly higher doses to some other organs.
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Dose-Response Relationship: Potency and Efficacy
Pharmacokinetic–Pharmacodynamic Relationship: Duration of Dose-Effect Relationship
Pharmacokinetic–Pharmacodynamic Relationship: Intensity of Dose-Effect Relationship
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Biological Effects of Radiation