Related Experiment Video
Updated: Jul 6, 2026

In vivo Evaluation of Mucociliary Clearance in Mice
Published on: December 18, 2020
High-resolution computed tomography evaluation of airway distensibility in asthmatic and healthy subjects
A Castagnaro1, A Rastelli, A Chetta
1Dipartimento di Scienze Cliniche, Patologie Respiratorie, Azienda Ospedaliero-Universitaria di Parma, Viale G. Rasori 10, 43100 Parma, Italy.
Purpose:
Airway-wall remodelling may result in reduced airway distensibility in bronchial asthma. This study evaluated the baseline airway calibre and distensibility in asthmatic patients by means of high-resolution computed tomography (HRCT).
Materials And Methods:
We studied seven patients (two men, age range 36-69 years) with chronic asthma [forced expiratory volume in the first second (FEV(1)) range: 30%-87% of predicted; FEV1/forced vital capacity (FVC) range 48%-75% of predicted) under stable clinical conditions and six healthy control subjects (three men, age range 29-50 years). In all subjects, HRCT scanning, at suspended end-expiratory volume, was performed at rest and during ventilation with 6 and 12 cmH(2)O by nasal insufflation with continuous positive airway pressure (nCPAP), both at baseline and after inhalation of 200 mug oxitropium bromide metered dose inhaler (MDI). External and lumen diameter (mm) of the right apical upper lobe bronchus were measured in all HRCT scans.
Results:
In asthmatics, 12 cmH(2)O insufflation significantly changed baseline lumen (3.3+/-0.7 mm vs. 3.8+/-0.6 mm; p<0.01) and external diameter (6.2+/-0.9 mm vs. 6.7+/-0.8 mm; p<0.05), whereas in healthy controls, both 6 and 12 cmH(2)O insufflation significantly changed baseline lumen diameter (4.0+/-1.6 mm vs. 4.8+/-1.6 mm and 4.7+/-1.7 mm; p<0.01). In asthmatic patients, oxitropium bromide inhalation significantly changed baseline lumen diameter (3.3+/-0.7 mm vs. 4.4+/-0.6 mm; p<0.05), whereas the application of 6 or 12 cmH(2)O insufflation did not modify any bronchial diameters. In healthy controls, oxitropium bromide inhalation significantly changed baseline lumen diameter (4.0+/-.6 mm vs. 5+/-1.5 mm; p<0.05). The application of 12 cmH(2)O but not of 6 cmH(2)O induced a significant change in lumen diameter (5.0+/-1.5 mm vs. 6,0+/-1.6 mm; p<0.05).
Conclusions:
Our results show that airway distensibility in asthmatic patients, as assessed by HRCT, can differ compared with that of healthy controls. HRCT can provide useful information on airway distensibility.
More Related Videos
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
08:26Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Physical Assessment of the Respiratory Tract I: Health History
Subjective Data
Subjective data provides vital information about the patient's health history and symptoms. This data is typically collected through interviews in which patients describe their experiences, symptoms, and concerns.
Health history and key...