Development and optimization of a system for comprehensive two-dimensional liquid chromatography with UV and mass
Mark Eggink1, Wilmar Romero, René J Vreuls
1VU University Amsterdam, Faculty of Science, Department of Analytical Chemistry and Applied Spectroscopy, De Boelelaan 1083, 1081 HV Amsterdam, The Netherlands. meggink@few.vu.nl
Abstract:
Comprehensive two-dimensional liquid chromatography (LC x LC) is a powerful tool for the separation of complex biological samples. This technique offers the advantage of simplified automation and greater reproducibility in a shorter analysis time than off-line two-dimensional separation systems. In the present study, an LC x LC system is developed enabling simultaneous UV and MS detection, and which can be easily converted to a conventional reversed-phase LC-UV/MS system. In LC x LC, a 60-min reversed-phase LC separation with a linear solvent gradient in the first dimension is coupled to a second-dimension separation on a mixed-mode cation-exchange/reversed-phase column with a modulation time of 60s. The isocratic separation in the second-dimension column is optimized by the use of a multi-step gradient where the organic and the ionic modifier are varied independently. Intraday (n=3) and interday (n=4) variability of the retention times were evaluated with the complete system and found to be 0.5% and 0.7%, respectively. Good linearity was observed in calibration curves for three different compounds varying in polarity.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...