Related Experiment Video
Updated: Jul 6, 2026

Preparation and Observation of Thick Biological Samples by Scanning Transmission Electron Tomography
Published on: March 12, 2017
On the structured imperfections of bulk GaSb using high resolution transmission electron microscopy
Ch B Lioutas1, G Zoulis, S Konidaris
1Department of Physics, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece.
Abstract:
GaSb is a promising III-V direct band gap semiconductor with sphalerite type FCC structure. Its band gap value has made it an excellent candidate for the conversion of infrared radiation to electricity. The wafers of GaSb, that were studied, originated from ingots grown with the Liquid Encapsulated Chochralski method. In all cases, Energy Dispersive X-ray Spectroscopy and Particle Induced X-ray Emission measurements demonstrated an excess of Sb. In the present work conventional transmission electron microscopy (CTEM) and high resolution electron microscopy (HRTEM) were used in order to determine the effect of the Sb excess in the structural characteristics of the material, mainly after thermal treatment. A structure model based on the ordering of the Sb antisites (Sb(Ga)) rather than the Ga vacancies (V(Ga)) is proposed for the observed modulation in small areas of the material.