Related Experiment Video
Updated: Jul 6, 2026

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Pulmonary levels of high-mobility group box 1 during mechanical ventilation and ventilator-associated pneumonia
Marieke A D van Zoelen1, Akitoshi Ishizaka, Esther K Wolthuls
1Center for Infection and Immunity Amsterdam, University of Amsterdam, Amsterdam, The Netherlands. M.A.vanZoelen@amc.uva.nl
Abstract:
High-mobility group box (HMGB) 1 is a recently discovered proinflammatory mediator that contributes to acute lung injury. We determined HMGB-1 levels in bronchoalveolar lavage fluid of patients during mechanical ventilation (MV) and ventilator-associated pneumonia (VAP). Bronchoalveolar lavage fluid was obtained from patients who were ventilated for 5 h because of an elective surgical procedure ("short-term MV"; n = 40) or for several days because of respiratory failure without acute lung injury ("long-term MV"; n = 10) and from patients who developed unilateral VAP (n = 4). Ten healthy volunteers served as controls. In healthy volunteers, HMGB-1 levels were low (median, 1.6 ngmL(-1); interquartile range [IQR], 0.7-3.7 ng mL(-1)). Although HMGB-1 levels were elevated after short-term MV, differences were not statistically significant compared with healthy volunteers (1.7 ng mL(-1); IQR, 0.8-8.5 ng mL(-1), P = 0.493 vs. healthy volunteers; P = 0.250 vs. start of MV). However, HMGB-1 levels were significantly higher in "long-term" MV patients (11.7 ng mL(-1); IQR, 8.7-37.0 ng mL(-1); P < 0.0001 vs. healthy volunteers). With unilateral VAP, HMGB-1 levels from the infected lung.were 17.4 (IQR, 8.5-23.2) ng mL(-1) (P = 0.014 vs. healthy controls); these levels were not different from those measured in the contralateral noninfected lung (P = 0.625). Summarized, long-term MV is associated with increased HMGB-1 levels in contrast to "short-term" MV. In addition, HMGB-1 levels during VAP are increased compared with healthy volunteers; however, they are not different from those found in patients intubated and mechanically ventilated for a similar period of time.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pneumonia II: Pathophysiology